CBFHR - PROCESS 44FDS FIRST DEVELOPER STARTER, 116

  • MSDS: CBFHR
  • Manufacturer: MILES INC
  • Product Name: PROCESS 44FDS FIRST DEVELOPER STARTER, 116
  • National Stock Number: 6750-00N067055
Product Identification

Product ID:PROCESS 44FDS FIRST DEVELOPER STARTER, 116
MSDS Date:10/01/1993
FSC:6750
NIIN:00N067055
MSDS Number: CBFHR

Responsible Party
MILES INC
100 CHALLENGER ROAD
RIDGEFIELD PARK, NJ 07660
US

Emergency Phone: 303-623-5716;800-424-9300(CHEMTREC)

Info Phone: 201-440-2500

Cage: MILES

Contractor
MILES INC
PITTSBURGH, PA 15205-9741 US

Telephone: 800-662-2927

Cage: MILES

Ingredients

ACETIC ACID (CERCLA)

CAS: 64-19-7

RTECS: AF1225000

Fraction By Weight: 15-20%

OSHA PEL 10 PPM

ACGIH TLV: 10 PPM; 15 STEL

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: 65-70%

OSHA PEL N/K

ACGIH TLV: N/K


POTASSIUM BROMIDE

CAS: 7758-02-3

RTECS: TS7650000

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE/SKIN: MAY CAUSE SEVERE
IRRITATION & BURNING. INHAL: NORMALLY NO PROBLEM, BUT INHAL OF MIST
COULD CAUSE RESP IRRIT. INGEST: MAY CAUSE SEVERE IRRIT/BURNING OF
MUCOUS MEMBS/DIGESTIVE TRACT. CH RONIC:COMPUTERIZED LITERATURE
SEARCH OFNATIONAL DATABASES DID NOT YIELD ANY CHRONIC EFTS ASSOC
W/THESE(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HLTH HAZ: MATERIALS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:EYES: IMMED FLUSH W/PLENTY OF RUNNING WATER FOR AT LEAST 15
MINS. OBTAIN MED ATTN. SKIN: FLUSH AFFECTED AREAS PROMPTLY W/WATER
FOR AT LEAST 15 MINS. REMOVE CONTAMD CLTHG. IN CASE OF CONTINUED
IRRIT, C ONSULT MD. INHAL: FOR OVEREXPOSURE, REMOVE TO FRESH AIR.
INGEST: OBTAIN IMMED MED ATTN.

Fire Fighting

Flash Point:NONCOMBUSTIBLE
Extinguishing Media:ANY APPLICABLE TO PRIMARY CAUSE OF FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT. EVAC PERSONNEL TO SAFE AREA. KEEP PERS
REMOVED & UPWIND OF FIRE.
Unusual Fire/Explosion Hazard:NONE.

Accidental Release

Spill Release Procedures:NOTE: REVIEW FIRE FIGHT PROCS & PERS PROT
BEFORE PROCEEDING W/CLEAN-UP. USE APPROP PERS PROT EQUIP DURING
CLEAN UP. DIKE SPILL. PVNT LIQ FROM ENTERING SEWERS, WATERWAYS/LOW
AREAS. SOAK UP W/SAWDUST, S AND, OIL DRY OR OTHER ABSORB MATL.
Neutralizing Agent:SPILL MAY BE NEUTRALIZED WITH POWDERED SODIUM
CARBONATE.

Handling

Handling and Storage Precautions:AVOID EYE & SKIN CONT & STORE IN
WELL-VENT AREA. KEEP CNTNR TIGHTLY CLSD. DO NOT STORE W/INCOMP
MATLS.
Other Precautions:DO NOT STORE OR CONSUME FOOD, DRINK OR TOBACCO IN
AREA WHERE THEY MAY BE CONTAMD W/THIS MATERIAL.

Exposure Controls

Respiratory Protection:NONE NEEDED WITH WORKING MIXTURES & NORMAL ROOM
VENTILATION(10 CHANGES OF AIR PER HOUR). USE NIOSH/MSHA APPROVED
RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN.
Ventilation:ROOM VENT IS SUFF. AVOID USE OF PROD IN UNVENT AREAS.
ALWAYS CONTROL AIRBORNE LEVELS Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS.
Other Protective Equipment:ANSI APPRVD EMER EYEWASH & DELUGE SHOWER.
CHEM RESIST APRON. DISP COVERALLS ARE OPTIONAL, DISP OF AFTER USE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
WASTE DISP METH: AUTHORITY AND MAY REQUIRE PRETREATMENT. DISPOSE OF
I/A/W LOCAL, STATE & FEDERAL REGULATIONS.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Spec Gravity:1.154(H*20=1)
pH:1.75
Solubility in Water:100%(WT)
Appearance and Odor:CLEAR & COLORLESS LIQUID W/VINEGAR LIKE ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ALKALI, OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CO*2, CARBON MONOXIDE.

Disposal

Waste Disposal Methods:RECOVER NONUSABLE FREE LIQD &/CONTAMD WATER &
DISP OF IN APPRVD & PERMITTED TREATMENT SYS; INCIN IS RECOM. REMOVE
NONUSABLE SOLID MATL &/CONTAMD SOIL, FOR DISP IN AN APPRVD &
PERMITTED LANDFILL. DISCH ARGE TO SEWER REQS APPROVAL OF
PERMITTING(SUPDAT)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.